NMP-1000
| SPECIFICATIONS
NMP-1000 LOG WIDE-RANGE CHANNEL |
| INPUT RANGE | 10-11 to 10-4 A or 10-10 A to 10-3 A in seven one decade ranges Self-bailing illuminated pushbutton or automatic range switching (manual or auto operator selected). Provision for remote range switching |
||||||||
| LINEARITY (LOG CONFORMITY) + 1% OF THE LINEAR | ± 1.0% of full scale upper 5 ranges; ±2.5% of full scale lower 2 ranges | ||||||||
| TEMPERATURE COEFFICIENT | ± 0.15% per °C maximum over 10° to 55°C | ||||||||
| CALIBRATION/TEST | 2 fixed currents for calibration, 1 adjustable current for multi-range function test and trip testing. HV trip test, test modes selected sequentially by front panel control | ||||||||
| RESPONSE TIME CONSTANTS | 1 msec 10-8 to 10-3 A, 10 msec 10-9 to 10-8 A; 100 msec to 10-11 to 10-9 | ||||||||
| OUTPUTS |
|
||||||||
| BISTABLE TRIPS |
|
||||||||
| POWER REQUIRED | 117 VAC ± 10% 50/60 Hz @ 1.0 A |