NLI-1000
| SPECIFICATIONS MODEL NLI-1000 INTERMEDIATE RANGE POWER MONITORING CHANNEL |
| INPUT RANGE | 1 x 10-10 to 1 x 10-3 Amperes | ||||||||||||||||
| LINEARITY | ± 3% of Full Scale | ||||||||||||||||
| TEMPERATURE | ± 0.15% / °C maximum in the range of 10° to 55°C | ||||||||||||||||
| CALIBRATION/TEST | 2 adjustable calibration points; local and remote Level and High Voltage trip test capability | ||||||||||||||||
| RESPONSE TIME |
|
||||||||||||||||
| BISTABLE TRIPS | High Voltage, High Power and Period 3 User Configurable (choose from power level or period, increasing or decreasing) Adjustable latching, with +5 volt Logic Level and two form "C" contacts per trip | ||||||||||||||||
| OUTPUTS |
|
||||||||||||||||
| POWER REQUIRED | 117 VAC ± 10% 50/60 Hz @ 1 Amp | ||||||||||||||||
| CHANNEL CONTROL | Local or Remote | ||||||||||||||||
| PULSE MODE INHIBIT | Inhibit of Level and Period Trips User Selectable |
| About Us | News & Information | Contact | Support | Procurement | Quality | Careers Energy Products | Terminal Automation Products | Radation Monotoring Systems | TRIGA | Gulftronic |
©General Atomics, All Rights Reserved