Model RD-55
Download PDF
The Model RD-55 detector assembly measures concentrations of gamma-emitting I131 isotopes adsorbed into an activated charcoal or silver zeolite filter. It can operate in a gamma flux background. The shield assembly consists of a steel-jacketed, horizontal, cast-lead cylinder with a center stainless-steel sleeve. An easily removable lead plug and an iodine-collection-cartridge assembly cap the front end of the shield. The opposite end is capped by a lead plug and an Am241-doped NaI (TI) detector assembly. The cylindrical shield and end plug provide full 4π shielding. There is an easily removable lead plug and an iodine collection cartridge assembly that cap the front end of the shield.
Specifications:
FILTER: TEDA-impregnated charcoal-filter or silver zeolite cartridge SHIELDING: 3- and 4-in. (7.6- and 10.2-cm) full 4π solid cast lead WEIGHT: Depends on shield thickness (see table of dimensions, back page) DETECTOR: 2-in. (5-cm) –diam x 2-in. (5-cm) –thick spectrometer-grade NaI (TI) crystal, optically coupled to 2-in. (5-cm) –diam photomultiplier tube. Am241 doped for thermal stability CHECKSOURCE: <10 μCi Ba133 SAMPLE PRESSURE: 15 psi (1.05 kg/cm2) gauge max SAMPLE HUMIDITY: Up to 95% relative humidity (noncondensing) |
SAMPLE TEMPERATURE: 35° to 120°F (2° to 49°C) SAMPLE FLOW: 3 scfm (14 liters/min) nominal INLET/OUTLET: 0.5-in. (1.3-cm) –diam stainless-steel tubing SAMPLER MATERIAL: Type 304 stainless steel or carbon steel except aluminum foil detector windows and selected other materials including O-ring seals PRESSURE DROP ACROSS INLET/OUTLET: Approximately 4-in. (10-cm) Hg with clean filters at nominal flow ELECTRICAL CONNECTORS: High voltage – MHV; signal – BNC |
Calibration
No energy response curve is provided, since only one energy level is of interest. The gamma spectrum of I131 shows the major photo peak at 364 keV and the digital signal processor single-channel analyzer 40 keV window. Detector I131 sensitivity is determined for this window.

*Average, rather than end-point, beta energies better represent actual detector operation, since beta particles from most isotopes are not
| Phosphor Size [in. (cm)] | Lead Thickness [in. (cm)]/Model No. |
cpm* ambient | cpm/mR/hr Co60 |
cpm/µCi I131 |
| 2 (5) diam. X 2 (5) thick | 3 (7.6)/RD-55-30 | 17 | 54 | 1.01 x 105 |
| 2 (5) diam. X 2 (5) thick | 4 (10.2)/RD-55-40 | 09 | 16 | 1.01 x 105 |
Minimum Detectable Activity (MDA) and Minimum Detectable Concentration (MDC) for RD-55-30.
Iodine Detector:
MDA and MDC for I131 in a 0.1-mR/hr Co60 gamma field:
MDA: 2.10 x 10-5 µCi (7.77 x 10-1 Bq) I131
MDC: 1.05 x 10-12 µCi/cm3 (3.89 x 10-2 Bq/m3) I131