Fixed-Filter Particulate and Iodine Detector

Model RE-58
Download PDF

The Model RD-58 is an offline radiation detector assembly for use on a process or continuous air monitor (CAM). It has two separate scintillation detectors: fixed-filter particulate and iodine. Both are contained in one compact 3-in.-thick 4π solid-lead shield, providing significant reductions in physical size, weight, and cost over earlier designs (which had two separate detector/shield assemblies) without reducing performance. Each detector can be easily and quickly serviced by just one person. Solenoid-actuated checksources are provided for each detector to verify proper operation. Various scintillator sizes are available, providing a choice of sensitivities and ranges.

Specifications

FILTERS: 1.9-in. (47-mm) –diam. HV LB5211 or equivalent (particulate); Scott TEDA-impregnated charcoal or silver zeolite filter cartridge (iodine)

SHIELDING: 3-in. (7.6-cm) full 4π solid cast-lead.

WEIGHT: 800 lb (364 kg) approximate

DETECTORS: 2-in. (5-cm) –diam. x 0.01-in. (0.03-cm) –thick beta phosphor, 2-in. (5-cm) –diam. photomultiplier tube (standard particulate detector); 2-in. (5-cm) –diam. x 2-in. (5-cm) –thick spectrometer-grade NaI (TI) crystal doped with Am241, optically coupled to a 2-in. (5-cm) –diam. photomultiplier tube (standard iodine detector)

CHECKSOURCES: <0.05 μCi Cl36 (beta), particulate detector; < 9 μCi Ba133 (gamma), iodine detector

SAMPLE PRESSURE: 15 lb/in.2 (1.05 kg/cm2) gauge (max)

SAMPLE FLOW: 3 ft3/min (1400 cm3/min) nominal

SAMPLE TEMPERATURE: 35° to 120°F (2° to 49°C)

INLET/OUTLET: 0.5-in. (1.3-cm) –diam. stainless steel tubing

SAMPLER MATERIAL: Type 304 stainless steel or carbon steel except aluminum foil detector windows and selected other materials including O-ring seals

PRESSURE DROP ACROSS INLET/OUTLET: Approximately 4 in. (10-cm) Hg with clean filters at nominal flow

ELECTRICAL CONNECTORS (ON EACH DETECTOR): High voltage – MHV; signal – BNC

Calibration

The energy response curve for the particulate detector is shown below. The gamma spectrum of I131 below, shows how the major photo peak at 364 keV is monitored with a SCA window of 40 keV (~10%). Also shown is the Am241 reference pulse for pulse height stabilization.

Channel Phosphor Size
[in. (cm)]
cpm*abmient cpm/mR/hr Co60 Sensitivity
(cpm/_Ci x 105)/Isotope
Particulate 2 (5) diam x 0.01
(0.03) thick plastic
39 36 1.15/ 1.11/ 1.44/
Cs137 Cl36 Rh106
Iodine 2 (5) diam x 2 (5)
thick NaI(TI)
17 54 1.01/  —  —
I131              
*Includes normal contributions from cosmic, natural, internal, and checksource backgournd

Minimum Detectable Activity (MDA) and Minimum Detectable Concentration (MDC)

Particulate Detector:

MDA and MDC for Cs137 particulates in a 0.1-mR/hr Co60 gamma field:

MDA: 2.46 x 10-6 µCi (9.10 x 10-1 Bq) Cs137

MDC: 9.15 x 10-14 µCi/cm3 (3.39 x 10-3 Bq/m3) Cs137

Iodine Detector:

MDA and MDC for I131 in a 0.1-mR/hr Co60 gamma field:

MDA: 2.10 x 10-5 µCi I131

MDC: 1.05 x 10-12 µCi/cm3 I131

MDC = 1.30 x 10-7 µCi/cm3 Xe133